{"id":604944072727,"title":"Chimney Data Plate","handle":"chimney-data-plate","description":"\u003cp\u003e\u003cspan\u003eChimney Data Plate\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eDescription:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChimney Notice plates are a Building Regulations requirement. They must be filled out and fixed near to the appliance or within a meter cupboard.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eInformation\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eInformation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eIt is the responsibility of the installer to ensure that the information written onto the plate is accurate and the installation complies with the requirements.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe relevant details can be written onto the plate with an Aerospace felt tip marker pen or similar permanent marker.\u003c\/p\u003e\n\u003cp\u003eThe information to be given depends on the actual installation and the following table provides examples together with identifying what is compulsory or optional information.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.topstak.co.uk\/uploads\/About_Us\/notice_plates.JPG\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e* The line numbers do not appear on the actual plate and are reference to the completion guidance given below.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ctable class=\"maintext\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompulsory\u003cbr\u003eor Optional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e1\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState the address of the property.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e2\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState the room where the hearth or beginning of the flue is located i.e. Lounge on ground floor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e3\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIf the chimney is a new installation state the type of system for example an ICS insulated metal chimney or Brick built with clay liners. If the chimney is existing, such as a masonry chimney you could state Existing masonry chimney.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e4\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIf the chimney i new state Not applicable new chimney see above. If the existing chimney has been relined state system used e.g. Topstak Multiflex “Class 1” flexible multifuel liner. If it is not being relined state Not relined.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e5\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDesignation Optional\u003cbr\u003eFlue size is Compulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThe designation information is optional and if known should be given as defined in BS EN 1443 or by the manufacturer. e.g. if the liner is Multiflex the designation would be T450 N2 S D3. The flue size must be stated e.g. 150mm dia. State cross sectional flue dimensions if a square or rectangular.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e6\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState what generic types of appliances and fuels the chimney\/liner can be used with. e.g. solid fuel open fire and or stove, gas appliance etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e7\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIf flue\/chimney product is suitable for condensing appliances state Yes. If it is not state No.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e8\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState what generic types of appliances can be used on the hearth e.g. solid fuel open fire and or stove, gas appliance etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e9\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOptional\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThis gives the option to state the make of the installed appliance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e10\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState date of installation. The space for “Ref” could be used to note the installer’s job number.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e11\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOptional\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThis space is for recording the optional information giving contact details of the person or firm carrying out the installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e12\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOptional\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThis space can be used for giving details on conditions on such as performance limitations e.g. false hearths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-24T07:47:11+00:00","created_at":"2018-03-09T12:06:27+00:00","vendor":"Wood Stove Store","type":"","tags":[],"price":250,"price_min":250,"price_max":250,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":7022276902935,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Chimney Data Plate","public_title":null,"options":["Default Title"],"price":250,"weight":0,"compare_at_price":null,"inventory_quantity":13,"inventory_management":"shopify","inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2042\/3445\/products\/31QdHkkHhyL.jpg?v=1524551931"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2042\/3445\/products\/31QdHkkHhyL.jpg?v=1524551931","options":["Title"],"content":"\u003cp\u003e\u003cspan\u003eChimney Data Plate\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eDescription:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChimney Notice plates are a Building Regulations requirement. They must be filled out and fixed near to the appliance or within a meter cupboard.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eInformation\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eInformation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eIt is the responsibility of the installer to ensure that the information written onto the plate is accurate and the installation complies with the requirements.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe relevant details can be written onto the plate with an Aerospace felt tip marker pen or similar permanent marker.\u003c\/p\u003e\n\u003cp\u003eThe information to be given depends on the actual installation and the following table provides examples together with identifying what is compulsory or optional information.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.topstak.co.uk\/uploads\/About_Us\/notice_plates.JPG\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e* The line numbers do not appear on the actual plate and are reference to the completion guidance given below.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ctable class=\"maintext\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompulsory\u003cbr\u003eor Optional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e1\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState the address of the property.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e2\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState the room where the hearth or beginning of the flue is located i.e. Lounge on ground floor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e3\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIf the chimney is a new installation state the type of system for example an ICS insulated metal chimney or Brick built with clay liners. If the chimney is existing, such as a masonry chimney you could state Existing masonry chimney.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e4\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIf the chimney i new state Not applicable new chimney see above. If the existing chimney has been relined state system used e.g. Topstak Multiflex “Class 1” flexible multifuel liner. If it is not being relined state Not relined.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e5\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDesignation Optional\u003cbr\u003eFlue size is Compulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThe designation information is optional and if known should be given as defined in BS EN 1443 or by the manufacturer. e.g. if the liner is Multiflex the designation would be T450 N2 S D3. The flue size must be stated e.g. 150mm dia. State cross sectional flue dimensions if a square or rectangular.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e6\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState what generic types of appliances and fuels the chimney\/liner can be used with. e.g. solid fuel open fire and or stove, gas appliance etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e7\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIf flue\/chimney product is suitable for condensing appliances state Yes. If it is not state No.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e8\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState what generic types of appliances can be used on the hearth e.g. solid fuel open fire and or stove, gas appliance etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e9\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOptional\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThis gives the option to state the make of the installed appliance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e10\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCompulsory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eState date of installation. The space for “Ref” could be used to note the installer’s job number.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e11\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOptional\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThis space is for recording the optional information giving contact details of the person or firm carrying out the installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e12\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOptional\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThis space can be used for giving details on conditions on such as performance limitations e.g. false hearths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

Chimney Data Plate

Product Description
Maximum quantity available reached.

Chimney Data Plate

Description

Description:

Chimney Notice plates are a Building Regulations requirement. They must be filled out and fixed near to the appliance or within a meter cupboard.

Information

Information:

It is the responsibility of the installer to ensure that the information written onto the plate is accurate and the installation complies with the requirements.

The relevant details can be written onto the plate with an Aerospace felt tip marker pen or similar permanent marker.

The information to be given depends on the actual installation and the following table provides examples together with identifying what is compulsory or optional information.

* The line numbers do not appear on the actual plate and are reference to the completion guidance given below.

 

Line no Compulsory
or Optional
Notes
1 Compulsory State the address of the property.
2 Compulsory State the room where the hearth or beginning of the flue is located i.e. Lounge on ground floor.
3 Compulsory If the chimney is a new installation state the type of system for example an ICS insulated metal chimney or Brick built with clay liners. If the chimney is existing, such as a masonry chimney you could state Existing masonry chimney.
4 Compulsory If the chimney i new state Not applicable new chimney see above. If the existing chimney has been relined state system used e.g. Topstak Multiflex “Class 1” flexible multifuel liner. If it is not being relined state Not relined.
5 Designation Optional
Flue size is Compulsory
The designation information is optional and if known should be given as defined in BS EN 1443 or by the manufacturer. e.g. if the liner is Multiflex the designation would be T450 N2 S D3. The flue size must be stated e.g. 150mm dia. State cross sectional flue dimensions if a square or rectangular.
6 Compulsory State what generic types of appliances and fuels the chimney/liner can be used with. e.g. solid fuel open fire and or stove, gas appliance etc.
7 Compulsory If flue/chimney product is suitable for condensing appliances state Yes. If it is not state No.
8 Compulsory State what generic types of appliances can be used on the hearth e.g. solid fuel open fire and or stove, gas appliance etc.
9 Optional This gives the option to state the make of the installed appliance.
10 Compulsory State date of installation. The space for “Ref” could be used to note the installer’s job number.
11 Optional This space is for recording the optional information giving contact details of the person or firm carrying out the installation.
12 Optional This space can be used for giving details on conditions on such as performance limitations e.g. false hearths.